Electrolysis & Electrowinning

Pilot-Scale Jacketed Electrolyte Heating and Cooling Tank

PriceOn request — the first reply carries a budget band and a lead time, within one business day

Jacketed PP electrolyte tank, 200 L or 500 L, holding 5–70 °C with a PTFE axial impeller at 0–120 rpm and a CPVC circulation loop.

Request a Quote

  • Built to order
    Engineered against your feed assay and throughput
  • Bench & pilot tested
    Sample testing before the flowsheet is frozen
  • Export documented
    Pre-tested, skid-mounted, documented for customs
  • EN / ES / RU / AR
    Technical support in four languages
SKU: pilot-scale-jacketed-electrolyte-heating-and-cooling-tank Category:

Electrowinning and electrorefining both want the cell feed at a steady temperature, and putting a heater inside the electrolyte is the wrong way to get it. This is a 200 L or 500 L PP tank with an outer jacket for water or water-glycol recirculation, so heat enters through the wall and never through the liquor.

Control loop

A PT100 probe and digital controller hold the set point with over-temperature cut-out and automatic switching between heating and cooling mode. A top-mounted gear drive turns a PTFE-coated axial impeller at 0–120 rpm to keep the tank uniform, and a CPVC centrifugal pump circulates through PP or CPVC valves with an in-line pressure gauge and thermometer.

Chemistry limits

PP wetted parts cover copper, cobalt and nickel electrolytes up to about 200 g/L H2SO4, with no fluoride and no chloride systems. Either of those moves the wetted parts to CPVC, PVDF or a lined design — and the jacket is unaffected, because it never contacts the electrolyte.

The vessel is atmospheric and non-pressure, built to GB or ASME where applicable, and shipped with material certificates and hydrotest documents. If your cell runs above ambient and the feed is batched, this tank is what keeps the temperature stable through the campaign instead of letting it drift with the batch.

Specifications

Working Capacity200 L or 500 L per tank; other volumes on request
Vessel MaterialPP tank body with outer jacket shell; PP wetted parts, CPVC or PVDF wetted parts optional for elevated temperature duty
Temperature Range5-70 deg C heating and cooling duty (to be confirmed by test work)
Jacket ServiceWater or water-glycol recirculation; electric immersion heater option for heating duty
AgitatorTop-mounted gear drive with PTFE-coated axial impeller, 0-120 rpm
Circulation LoopCPVC centrifugal pump, PP/CPVC ball valves, inline pressure gauge and thermometer
Temperature ControlDigital controller with PT100 probe, over-temperature cut-out, heating and cooling mode switching
Applicable MediaCopper, cobalt and nickel electrolytes, H2SO4 up to 200 g/L, no fluoride and no chloride systems; fluoride or chloride duty requires lined, CPVC or titanium design
Nozzles and DrainDN25/DN50 PN10 PP-CPVC side nozzles, bottom drain valve
ComplianceAtmospheric non-pressure vessel; design to GB or ASME code where applicable, material certificates and hydrotest documents supplied with vessel

Values are the documented specifications for this model. Final dimensions are confirmed on the approved drawing before production.

+86 19386680947
Request a QuoteWhatsApp