Reactor de lixiviación asistida por ultrasonidos de laboratorio

PrecioBajo pedido: la primera respuesta incluye un rango de presupuesto y un plazo de entrega en un día hábil

Reactor de lixiviación por ultrasonidos, 2–10 L en vidrio GG17 de doble camisa, sonda de 20 kHz a 300–1500 W, 5–80 °C, para lixiviación de óxidos y escorias refractarias.

Request a Quote

  • Built to order
    Engineered against your feed assay and throughput
  • Bench & pilot tested
    Sample testing before the flowsheet is frozen
  • Export documented
    Pre-tested, skid-mounted, documented for customs
  • EN / ES / RU / AR
    Technical support in four languages
SKU: laboratory-ultrasonic-assisted-leaching-reactor-es Categories: ,

Reactor de 2, 5 o 10 L en vidrio GG17 de doble camisa con sonda de titanio de 20 kHz y 300–1500 W, sumergida hasta el fondo para que la nube de cavitación esté donde están los sólidos. El generador permite 20–100% de amplitud y modo pulsado.

Un agitador de PTFE a 0–600 rpm mantiene la pulpa en suspensión entre pulsos, y la camisa, alimentada por un baño externo, sostiene 5–80 °C. Si la velocidad está limitada por pasivación superficial o por una fase encapsulada, el ultrasonido cambia el resultado; en lixiviación de óxidos corriente añade coste sin mover la curva.

Specifications

Reactor Capacity2 L, 5 L or 10 L double-jacketed borosilicate glass (GG17) vessel; final sizing to be confirmed by test work
Vessel MaterialGG17 borosilicate glass with PTFE lid seals; suitable for H2SO4
Ultrasonic System20 kHz titanium sonotrode probe with piezo transducer, 300-1500 W adjustable output, dip length to vessel bottom
Ultrasonic GeneratorMicroprocessor generator with pulse mode, amplitude control 20-100% and overtemperature protection
AgitationPTFE-coated overhead stirrer, 0-600 rpm variable speed, for bulk suspension maintenance during sonication
Temperature Range5-80 C via jacket served by external circulating bath; PT100 probe with overtemperature interlock
Operating ModeAtmospheric batch operation, intermittent or continuous sonication (duty cycle to be confirmed by test work)
Drain and SamplingBottom PTFE drain valve and side sampling port for kinetic profiles
Wetted MaterialsTitanium sonotrode, PTFE gaskets, borosilicate glass, 316L frame; fluoride or high-chloride systems require titanium-wetted or PTFE-lined options
ApplicationsCavitation-enhanced leaching of refractory oxides and slags, secondary-resource leaching, desliming and reagent screening tests

Values are the documented specifications for this model. Final dimensions are confirmed on the approved drawing before production.

+86 19386680947
Request a QuoteWhatsApp