Laboratory Sulfide Precipitation Reactor (NaHS Dosing with H2S Scrubber)
PriceOn request — the first reply carries a budget band and a lead time, within one business day
Lexin-tech is professional customized China Laboratory Sulfide Precipitation Reactor (NaHS Dosing with H2S Scrubber) manufacturers,supplier and factory, specialized in providing customized Laboratory Sulfide Precipitation Reactor (NaHS Dosing with H2S Scrubber) in stock with wholesale price. For quotation, contact us now.
This laboratory sulfide precipitation reactor is configured for selective metal removal from leach liquor and strip solution by NaHS or Na2S dosing under ORP control: a gas-tight bolted PP reactor with pH and ORP probe ports, a metered reagent day tank, and an integrated caustic packed scrubber on the off-gas line so that H2S is neutralised before discharge. Typical duty is Cu, Ni, Co, Zn or Cd sulfide precipitation ahead of solid-liquid separation, or polishing of pregnant liquor before solvent extraction.
- Built to order
Engineered against your feed assay and throughput - Bench & pilot tested
Sample testing before the flowsheet is frozen - Export documented
Pre-tested, skid-mounted, documented for customs - EN / ES / RU / AR
Technical support in four languages
Lexin-tech is professional customized China Laboratory Sulfide Precipitation Reactor (NaHS Dosing with H2S Scrubber) manufacturers,supplier and factory, specialized in providing customized Laboratory Sulfide Precipitation Reactor (NaHS Dosing with H2S Scrubber) in stock with wholesale price. For quotation, contact us now.
This laboratory sulfide precipitation reactor is configured for selective metal removal from leach liquor and strip solution by NaHS or Na2S dosing under ORP control: a gas-tight bolted PP reactor with pH and ORP probe ports, a metered reagent day tank, and an integrated caustic packed scrubber on the off-gas line so that H2S is neutralised before discharge. Typical duty is Cu, Ni, Co, Zn or Cd sulfide precipitation ahead of solid-liquid separation, or polishing of pregnant liquor before solvent extraction.
Specifications
| Reactor Capacity | 50 L / 100 L working volume as standard, 200 L version on request; 20-80% fill |
|---|---|
| Vessel and Lid Material | PP shell with 20 mm PP flange ring and EPDM gasket; bolted gas-tight lid for H2S containment |
| Wetted Parts Options | PP as standard; PVDF or PP/FRP lined body with PTFE-lined probe pockets for chloride-bearing liquors |
| Temperature Range | Ambient to 70 °C (PP limit 80 °C); unheated standard, jacketed version on request |
| pH Control | pH 1.5-5.0 with pH transmitter and lime or caustic dosing loop |
| ORP Control and NaHS Dosing | ORP -200 to +400 mV (Ag/AgCl) endpoint control; 0-20 L/h diaphragm metering pump, 20 L PE day tank, calibration cylinder |
| Off-Gas Scrubbing | Transparent packed column DN150 x 1000 mm with PP Pall ring bed, 5 wt% NaOH recirculation pump and demister; outlet H2S target below 5 ppm (to be confirmed by test work) |
| Agitation | Top-entry 0.37-0.75 kW geared drive, PTFE-lined shaft, pitched-blade impeller, 100-400 rpm VFD |
| Solids Handling | 60 degree conical bottom with DN50 flush valve and slurry recirculation loop; batch filtration downstream |
| Applicable Systems | H2SO4 up to 150 g/L, chloride-free and fluoride-free liquors; Cu, Ni, Co, Zn and Cd removed as sulfide; chloride or fluoride service requires PVDF, CPVC or titanium wetted parts |
Values are the documented specifications for this model. Final dimensions are confirmed on the approved drawing before production.